SJ900RT

● Rack/Tower design
● High frequency and true double-conversion
● DSP digital control technology
● Input power factor correction (PFC)
● Wide input voltage range (110V-300V)
● Output power factor 0.9
● Cold start
● Frequency adaptive
● ECO mode operation for energy saving
● Selectable output voltage via LCD
● Output bypass settable for 1,2,3KVA via LCD

● 50Hz/60Hz frequency converter mode available on 6-10KVA

● Selectable battery low voltage via LCD
● Automatically diagnose when starts
● Advanced battery management (ABM)
● Short circuit and overload protection
● Automatically charging battery at UPS off mode
● Fan speed auto control when load varies
● Standard RS232 communication port and RJ45 protection
● Optional USB/SNMP communication port
● Optional emergency power off (EPO)
● Optional extension battery bank
● Optional N+X redundancy parallel on 6-10KVA

MODEL

SJ901IIRT

SJ902IIRT

SJ903IIRT

SJ906IIRT

SJ9010IIRT

Capacity

1KVA/900W

2KVA/1800W

3KVA/2700W

6KVA/5400W

10KVA/9000W

INPUT
Rated Voltage

208V/220V/230V/240VAC

Voltage Range

Half load (115-295)±5VAC

Full load (145-295)±5VAC

Half load (115-295)±5VAC

Full load (165-295)±5VAC

Frequency

45-55Hz±0.5% or 55-65Hz±0.5% (Auto Sensing)

40-70Hz±0.5% (Auto Sensing)

Power Factor

≥0.98

≥0.99

Bypass Voltage Range

Rated output voltage-34V ~ Rated output voltage+32V

160V ~ Rated output voltage+32V

OUTPUT
Voltage

208V/220V/230V/240VAC Setting available via LCD

Voltage Regulation

±1%

Frequency

Synchronized with utility on AC mode;50/60±0.2Hz on battery mode

Waveform

Pure sine wave

Crest Factor

3:1

Harmonic Distortion

≤3%(Linear load);≤5%(Non-linear load)

≤2%(Linear load);≤5%(Non-linear load)

Transfer Time

AC mode to battery mode :0ms

Inverter model to bypass mode:4ms(Typical)

AC mode to battery mode :0ms

Inverter model to bypass mode:0ms

Overload Capability

105%-150%:Transfer to bypass after 30s;

>150%: Transfer to bypass after 300ms

105%-125%:Transfer to bypass after 3mins;

125%-150%: Transfer to bypass after 30s;

>150%: Transfer to bypass after 100ms

EFFICIENCY
AC Mode

≥90%

≥92%

Battery Mode

≥87%

≥91%

ECO Mode

≥98%

≥98%

BATTERY
DC Voltage

24V

48V

72V

192V

Inbuilt Battery of Standard Model

2*9Ah

4*9Ah

6*9Ah

16*7Ah

16*9Ah

Charge Current Standard Model

1A

Long Time Model

6A

1A/3A/5A/8A

Typical Recharge Time

8 hours recover to 90% capacity

ALARM
Utility Failure

Beep/4s

Battery Low

Beep/1s

Overload

Beep Twice/1s

UPS Fault

Long Beep

ENVIRONMENT
Humidity

20~90% RH @ 0~40℃(non-condensing)

Noise Level

≤50dB (1m)

≤55dB (1m)

MANAGEMENT
Standard RS-232 ,Optional USB

Supports Windows 98/2000/2003/XP/Vista/2008/Windows7/8

Optional SNMP

Power management from SNMP manager and web browser

PHYSICAL
Long

Time

Model

Dimension(mm) W*D*H

440*468*88

440*555*132

Packing Dimension(mm) W*D*H

530*590*170

535*660*215

Net/Gross Weigh(kg)

8.6/12.0

10.7/14.1

12.3/15.7

16.4/20.7

17.1/21.4

Standard

Model

Dimension(mm) W*D*H

440*468*88

440*690*88

440*555*132(UPS)

440*555*132(BAT)

Packing Dimension(mm) W*D*H

530*590*170

530*825*170

535*660*215(UPS)

540*685*235(BAT)

Net/Gross Weigh(kg)

14.3/17.7

23.4/26.8

29.7/33.1

16.4/20.7(UPS)

17.1/21.4(UPS)

43.6/47.1

49.6/53.1

SJ900IIRT 1-10KVA user manual
SJ900IIRT 1-10KVA Datasheets